Print Page Print Page Pdf Page Pdf Page Add Page to Report Add To Report Report Center Report Center
Every attempt has been made to provide current, accurate, and consistent data in this database. There may be some differences due to sources, methodologies, or timing of data-assembly.
Water Information

Utility Rate Schedule - Monthly Charge for Water Service

 

Supply Source

Corpus Christi's primary water supply is the Choke Canyon / Lake Corpus Christi Reservoir System within the Nueces River Basin. These reservoirs are fed by the Nueces, Frio and Atascosa Rivers. The upper reaches of these rivers flow through the Edwards Aquifer Recharge Zone. During periods of low flow, most of the river flow north of the aquifer is captured by the aquifer, excluding the northern portion of the basin from the reservoirs' watershed.

Additional water is supplied through Lake Texana. The Mary Rhodes Pipeline delivers water to the O.N. Stevens Water Treatment Plant in Corpus Christi.

 

Treatment

Raw water is diverted by the City of Corpus Christi is treated at the O. N. Stevens Water Treatment Plant located in the Five Points area of the City. The plant was initially constructed in 1954. It has a rated capacity of producing up to 167 million gallons a day. On average, the plant produces 80 million gallons of water, which is equivalent to 40.

 

Quality - Raw Water

City of Corpus Christi Water Department
Nueces River Raw Water Quality For Fiscal Year 2006 - 2007

Date of Sample

1-
Aug

12-
Sep

3-
Oct

7-
Nov

12-
Dec

1-
Jan

6-
Feb

6-
Mar

10-
Apr

8-
May

6/5/2007

Average

Median

Min.

Max.

 
Aluminum
(mg/L)

1.5

2.1

1.9

3.2

2.1

2.3

2.3

3.1

2.6

2.6

4.2

2.5

2.3

1.5

4.2

Sodium
(mg/L)

170

173

173

120

174

224

216

148

152

116

82

158.9

170.0

82.0

224.0

Iron
(mg/L)

0.68

0.82

0.78

1.4

0.84

0.92

1

1.3

1.1

0.88

1.7

1.0

0.9

0.7

1.7

Manganese
(mg/L)

0.08

 < 0.05

0.05

0.08

     < 0.05

<0.05

0.05

0.06

0.05

<0.05

0.08

0.1

0.1

0.1

0.1

Copper
(mg/L)

    < 0.05

 < 0.05

     < 0.05

   < 0.05

     < 0.05

<0.05

<0.05

<0.05

    < 0.05

<0.05

<0.05

 

 

0.0

0.0

Lead
(mg/L)

    < 0.005

 < 0.005

    < 0.005

   < 0.005

    < 0.005

<0.005

<0.005

<0.005

   < 0.005

<0.005

<0.05

 

 

0.0

0.0

Bromide
(mg/L)

0.7

0.7

0.7

0.5

0.5

0.9

1

0.5

0.5

0.2

0.1

0.6

0.5

0.1

1.0

Conductivity
(umhos/cm)

1350

1479

1518

1175

1550

1760

1500

1350

1306

1072

838

1354.4

1350.0

838.0

1760.0

T. Alk.
(mg CaCO3/L)

145

148

164

153

175

172

178

160

160

152

149

159.6

160.0

145.0

178.0

Calcium
(mg/L)

110

76

110

112

140

134

134

111

118

87

73

109.5

111.0

73.0

140.0

Chloride
(mg/L)

320

327

340

270

339

395

368

276

270

218

134

296.1

320.0

134.0

395.0

Fluoride
(mg/L)

< 0.20

 < 0.20

 < 0.20

<0.2

0.20

0.28

0.20

0.20

    < 0.20

<0.20

     <0.20

0.2

0.2

0.2

0.3

T. Hardness
(mg CaCO3/L)

318

316

327

286

342

364

360

300

320

264

228

311.4

318.0

228.0

364.0

pH

8.3

8.0

8.0

8.2

7.6

7.6

7.6

7.3

7.8

7.6

8.0

7.8

7.8

7.3

8.3

Silica, Dissolved
(mg/L)

28

27

30

25

28

25

24

22

22

21

17

24.5

25.0

17.0

30.0

Sulfate
(mg/L)

101

100

101

81

96

118

122

91

85

68

53

92.4

96.0

53.0

122.0

Turbidity
(NTU)

15

24

20

40

21

23

24

32

30

28

32

26.3

24.0

15.0

40.0

Dissolved Solids
(mg/L)

864

870

924

735

994

926

781

784

616

446

794.0

824.0

446.0

994.0

 
Suspended Solids
(mg/L)

21

29

19

40

4

13

11

13

26

45

22.1

20.0

4.0

45.0

 

Source: City of Corpus Christi

 
City of Corpus Christi Water Department
Lake Texana Raw Water Quality For Fiscal Year 2006 - 2007

Date of Sample

1
-Aug

12-
Sep

3-
Oct

7-
Nov

12-
Dec

1-
Jan

6-
Feb

6-
Mar

10-
Apr

8-
May

6/5/2007

Average

Median

 Min.

   Max.

 

Aluminum
(mg/L)

2.4

1.7

2.3

4.5

7.4

7.8

12

13

13

14

8.8

7.9

7.8

1.7

14.0

Sodium
(mg/L)

21

16

16

14

13

13

8.5

7.0

5.6

5.8

26

13.3

13.0

5.6

26.0

Iron
(mg/L)

1.1

0.7

0.94

2.1

3.1

3.4

5.1

4.8

4.9

4.5

3.6

3.1

3.4

0.7

5.1

Manganese
(mg/L)

    < 0.05

 < 0.05

     < 0.05

    < 0.05

     < 0.05

<0.05

<0.05

<0.05

   < 0.05

<0.05

<0.05

 

 

0.0

0.0

Copper
(mg/L)

    < 0.05

 < 0.05

     < 0.05

   < 0.05

     < 0.05

<0.05

<0.05

<0.05

     < 0.05

<0.05

<0.05

 

 

0.0

0.0

Lead
(mg/L)

    < 0.005

 < 0.005

    < 0.005

 < 0.005

    < 0.005

<0.005

<0.005

<0.005

    < 0.005

<0.005

<0.005

 

 

0.0

0.0

Bromide
(mg/L)

0.1

0.1

   < 0.1

     < 0.1

0.1

0.1

0.1

0.1

0.1

0.1

<0.1

0.1

0.1

0.1

0.1

Conductivity
(umhos/cm)

231

259

271

214

215

207

124

143

123

130

152

188.1

207.0

123.0

271.0

T. Alk.
(mg CaCO3/L)

84

85

79

72

70

70

45

 

    < 100

46

51

66.9

70.0

45.0

85.0

Calcium
(mg/L)

26

30

30

24

24

25

18

19

      < 20

18

22

23.6

24.0

18.0

30.0

Chloride
(mg/L)

32

24

30

16

25

24

14

14

       < 10

11

10

20.0

20.0

10.0

32.0

Fluoride
(mg/L)

    < 0.20

   < 0.20

   < 0.20

<0.2

      < 0.20

<0.20

<0.20

<0.20

      < 0.20

<0.20

<0.20

#DIV/0!

#NUM!

0.0

0.0

T. Hardness
(mg CaCO3/L)

90

90

96

80

90

98

60

84

62

84

74

82.5

84.0

60.0

98.0

pH

8.1

7.8

7.9

8

7.3

7.8

7.3

7.0

7.0

7.1

7.0

7.5

7.3

7.0

8.1

Silica, Dissolved
(mg/L)

13

15

16

14

19

14

14

16

13

17

17

15.3

15.0

13.0

19.0

Sulfate
(mg/L)

12

12

16

8

8

27

13

1

1

1

6

9.5

8.0

1.0

27.0

Turbidity
(NTU)

31

20

27

55

70

70

110

110

110

120

80

73.0

70.0

20.0

120.0

Dissolved Solids
(mg/L)

153

137

171

146

161

173

164

202

174

177

165.8

167.5

137.0

202.0

 

Suspended Solids
(mg/L)

9

10

22

23

7

13

11

9

14 10 12.8 10.5 7.0 23.0  

Source: City of Corpus Christi
 

Quality: Treated Water - Holly Road
City of Corpus Christi Water Department
Water Quality Analysis for Holly Road Sampling Location Fiscal Year 2006 - 2007

Date of Sample

1-
Aug

12-
Sep

3-
Oct

7-
Nov

12-
Dec

1-
Jan

6-
Feb

6-
Mar

10-
Apr

8-
May

5-
Jun

Average

Median

Min.

Max.

Aluminum
(mg/L)

0.15

0.16

0.18

0.16

0.16

0.12

0.14

0.15

0.14

0.22

0.23

0.16

0.16

0.12

0.23

Sodium
(mg/L)

118

92

90

83

96

110

155

160

100

80

59

103.9

96.0

59.0

160.0

Iron
(mg/L)

 < 0.05

 < 0.05

 < 0.05

<0.05

    < 0.05

<0.05

<0.05

<0.05

<0.05

<0.05

<0.05

 

 

0.0

0.0

Manganese
(mg/L)

 < 0.05

 < 0.05

 < 0.05

<0.05

    < 0.05

<0.05

<0.05

<0.05

<0.05

<0.05

<0.05

 

 

0.0

0.0

Copper
(mg/L)

 < 0.05

 < 0.05

 < 0.05

<0.05

    < 0.05

<0.05

<0.05

<0.05

<0.05

<0.05

<0.05

 

 

0.0

0.0

Lead
(mg/L)

 < 0.005

 < 0.005

 < 0.005

<0.005

   < 0.005

<0.005

<0.005

<0.005

<0.005

<0.005

<0.005

 

 

0.0

0.0

Bromide
(mg/L)

0.4

0.3

0.1

0.1

0.1

0.1

0.3

0.3

0.1

<0.1

<0.1

0.2

0.1

0.1

0.4

Conductivity
(umhos/cm)

925

870

804

720

927

1050

747

1450

906

746

597

885.6

870.0

597.0

1450.0

T. Alk.
(mg CaCO3/L)

100

99

104

102

106

109

105

140

<100

94

92

105.1

103.0

92.0

140.0

Calcium
(mg/L)

72

61

62

67

66

70

80

110

101

63

44

72.4

67.0

44.0

110.0

Chloride
(mg/L)

200

166

160

142

176

158

254

289

163

132

80

174.5

163.0

80.0

289.0

Fluoride
(mg/L)

0.47

0.77

 < 0.20

0.78

    < 0.20

0.82

0.20

0.75

0.82

0.89

     <0.20

0.7

0.8

0.2

0.9

T. Hardness
(mg CaCO3/L)

210

205

186

176

204

212

276

308

260

178

160

215.9

205.0

160.0

308.0

pH

7.8

7.6

7.7

7.7

7.2

7.6

7

7.4

7.5

7.4

7.8

7.5

7.6

7.0

7.8

Silica, Dissolved
(mg/L)

17

18

19

16

17

16

16

20

13

13

12

16.1

16.0

12.0

20.0

Sulfate
(mg/L)

97

82

77

68

72

78

116

124

90

0.22

62

78.7

78.0

0.2

124.0

Turbidity
(NTU)

0.20

0.15

0.20

0.30

0.15

0.15

0.30

0.20

0.15

0.25

0.25

0.2

0.2

0.2

0.3

Dissolved Solids
(mg/L)

584

505

474

413

505

666

820

544

306

535.2

505.0

306.0

820.0

   

Suspended Solids
(mg/L)

    < 2

   < 2

 < 2

<2

<2

<2

<2

<2

<2

<2

 

 

0.0

0.0

 

Source: City of Corpus Christi

 
Quality: Treated Water - O.N. Stevens Plant
 
Time: 12:00 AM


Production in MG


62.35
Raw Water Blend
Percentage
Nueces River
82.00
Lake Texana
18.00
Conductivity in umho/cm
1221.00
Hardness in mg CaCO3/L
258.00
Hardness in grains/gal
15.10
Chlorine Residual in mg/l
3.90

Disclaimer: Data are subject to change due to weather conditions